Deep Inspiration Breath Hold in Left Sided Whole Breast Radiotherapy: a single-center experience
PO-1196
Abstract
Deep Inspiration Breath Hold in Left Sided Whole Breast Radiotherapy: a single-center experience
Authors: FRANCESCA MAURIZI1, Francesca Palleri2, Mirko Mazza1, Alberto Ciarmatori2, Claudio Blasi1, Elisabetta Argazzi2, Giorgia Capezzali1, Mariangela La Macchia1, Gian Luca Moroni1, Stefano Giancaterino2, Marco Bruno Luigi Rocchi3, Monica Bono2, Feisal Bunkheila1
1Radiation Oncology Unit, Az. Osp. Ospedali Riuniti Marche Nord, Pesaro, Italy; 2Medical Physics and Health Technology Unit, Az. Osp. Ospedali Riuniti Marche Nord, Pesaro, Italy; 3Department of Biomolecular Sciences, University of Urbino Carlo Bo, Urbino, Italy
Show Affiliations
Hide Affiliations
Purpose or Objective
After breast
conserving surgery, adjuvant radiotherapy (RT) to the conserved breast reduces
the risk of recurrence and improves overall survival. In previous studies, late
cardiac toxicity appeared to be a rare but relevant sequelae related to unavoidable irradiation to the heart during left sided radiation treatments. The aim of this analysis is the evaluation of the benefits of Deep Inspiration
Breath-Hold (DIBH) technique compared with Free Breathing (FB) in the treatment
of breast cancer patients (pts).
Material and Methods
The patient selection included women undergoing whole breast radiotherapy (WBRT) after lumpectomy
for left sided breast cancer. The respiratory gating systems were optical
surface scanning devices: Sentinel for the CT simulation and Catalyst HD for
the radiation treatment. Respiratory signal has been monitored in the lower part of the sternum at
the height of the xiphoideus process. The chosen gating window was between 3-5
mm. The patient
training was carried out with electronic eyeglasses (video coaching). Only
patients able to follow the training to find their individual deep inspiration
level and to retain breathing for at least 20 seconds have been included.
Patients underwent the planning CT in the supine position with the acquisition
of both Free Breathing (FB) and DIBH image sets. Contouring and treatment
planning were realized on both CT studies with Monaco TPS. From March 2019 to
September 2021, 97 patients (median age: 53 years, range: 24-75) successfully completed DIBH
simulations. Eighty-six patients were treated with 40 Gy in 15 fractions (fr) and 11 pts with 50 Gy in 25 fr. The following dosimetric parameters were evaluated and compared for
statistically significant differences using the Mann-Whitney Test in both FB
and DIBH plans: mean heart dose (MHD), D2cc and V13, left mean lung dose (MLD)
and V18 in hypofractionation or V20 in conventional treatments.
Results
Seventeen plans were realized with VMAT modality and 80 with 3DCRT planning
technique. All cardiac dosimetric parameters were significantly improved
with the use of DIBH: MHD and D2cc decreased of 33% (1.61 Gy FB vs 1.09 Gy DIBH;
p<0.0001) and 56% (17.72 Gy FB vs 7.76 Gy DIBH; p<0.0001) respectively.
For left MLD the average dose reduction was 6% with DIBH (p=0.04). Patients treated with VMAT
modality experienced a significantly larger reduction in MLD (10.5%). The
difference in Lung V18 (or V20) was not statistically significant.
Conclusion
DIBH with surface tracking systems results to be a
feasible and effective option for cardiac dose sparing. This benefit could
potentially reduce long term major coronary events. Clinical correlations are
expected.