All data were acquired in a water tank MP3-XS (PTW, Freiburg, Germany), using a microSilicon PTW60023 (mS60023), a micro diamond PTW60019 (mD60019), ionisation chambers PTW31010 & PTW31021 (IC31010 & IC31021), a plastic scintillation detector (PSD) (Blue Physics LLC, Tampa, USA) and EBT-XD Gafchromic film (Ashland, Covington, USA)
At SSD 450mm and 30mm depth, output factors (OF) and cross-profiles were acquired for all collimators s (25, 20, 15, 12.5, 10, 7.5, 5, 4mm) with the mS60023, mD60019, IC31021, EBT-XD and PSD, while depth-dose-curves (DDC) were measured with the mS60023, mD60019, PSD and, only for the collimator of 25mm, with the IC31021.